Avicenna Journal of Dental Research، جلد ۷، شماره ۲، صفحات ۰-۰
|
|
|
عنوان فارسی |
The Comparison of Vertical Margin Discrepancy in Casting Fabricated With Metal Ring, Ringless and Metal Ring With Hygroscopic Expansion Investment Systems |
|
چکیده فارسی مقاله |
Conclusions The castings fabricated from the ringless technique with non-precious alloy are acceptable. This investing system is useable for the fabrication of fixed restorations. Results After statistical evaluation, the following results were obtained: the mean vertical margin discrepancy for conventional investing was 156.72 ± 64.67µ; for the ringless technique it was 117.3 ± 26.77µ; and for the conventional metal ring technique with hygroscopic expansion it was 96.15 ± 38.31 µ. There is a significant difference between castings of the conventional investing technique and the ringless and ring plus hygroscopic expansion techniques (P < 0.001). No significant difference was found between the ringless and ring plus hygroscopic expansion techniques (P = 0.183). Objectives The current study aimed to determine and compare the mean values of vertical margin discrepancies of castings in three investing procedures: the ringless technique and conventional investing technique. Materials and Methods In the first step, 39 coping wax patterns for Porcelain fused to metal restoration (P.F.M). With chamfer finish line were fabricated on the metal die and then divided into three groups of 13. The first group used conventional investing (with ring and liner), the second group used the ringless technique and the third group used the conventional ring technique with liner and hygroscopic expansion. All groups were invested using Thermovest phosphate bonded investment. Then wax patterns were cast with Ni-Cr alloy (super cast). Castings were divested, cleaned and seated on the metal die after minimal internal surface adjustment. The vertical margin discrepancy was measured in four sites: on the buccal, lingual, mesial and distal surfaces of the die. Castings were measured on an optical microscope. The vertical margin discrepancy in each group was used for statistical analysis. Background The use of casting ring to produce accurate casting has been challenged with the introduction of a ringless casting technique. This study compared the vertical margin discrepancy of castings fabricated with the ringless technique, conventional (ring and liner) technique and conventional technique with hygroscopic expansion investment systems. |
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
The Comparison of Vertical Margin Discrepancy in Casting Fabricated With Metal Ring, Ringless and Metal Ring With Hygroscopic Expansion Investment Systems |
|
چکیده انگلیسی مقاله |
Conclusions The castings fabricated from the ringless technique with non-precious alloy are acceptable. This investing system is useable for the fabrication of fixed restorations. Results After statistical evaluation, the following results were obtained: the mean vertical margin discrepancy for conventional investing was 156.72 ± 64.67µ; for the ringless technique it was 117.3 ± 26.77µ; and for the conventional metal ring technique with hygroscopic expansion it was 96.15 ± 38.31 µ. There is a significant difference between castings of the conventional investing technique and the ringless and ring plus hygroscopic expansion techniques (P < 0.001). No significant difference was found between the ringless and ring plus hygroscopic expansion techniques (P = 0.183). Objectives The current study aimed to determine and compare the mean values of vertical margin discrepancies of castings in three investing procedures: the ringless technique and conventional investing technique. Materials and Methods In the first step, 39 coping wax patterns for Porcelain fused to metal restoration (P.F.M). With chamfer finish line were fabricated on the metal die and then divided into three groups of 13. The first group used conventional investing (with ring and liner), the second group used the ringless technique and the third group used the conventional ring technique with liner and hygroscopic expansion. All groups were invested using Thermovest phosphate bonded investment. Then wax patterns were cast with Ni-Cr alloy (super cast). Castings were divested, cleaned and seated on the metal die after minimal internal surface adjustment. The vertical margin discrepancy was measured in four sites: on the buccal, lingual, mesial and distal surfaces of the die. Castings were measured on an optical microscope. The vertical margin discrepancy in each group was used for statistical analysis. Background The use of casting ring to produce accurate casting has been challenged with the introduction of a ringless casting technique. This study compared the vertical margin discrepancy of castings fabricated with the ringless technique, conventional (ring and liner) technique and conventional technique with hygroscopic expansion investment systems. |
|
کلیدواژههای انگلیسی مقاله |
|
|
نویسندگان مقاله |
محمود صبوحی | mahmood sabouhi department of prosthetics, school of dentistry, isfahan university of medical sciences, isfahan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)
مراد hedayatipanah | morad hedayatipanah department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran; department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran. tel 98-9188413990, fax 98-813838108
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
|
|
نشانی اینترنتی |
http://www.avicennajdr.com/index.php?page=article&article_id=24834 |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
10.17795/ajdr-24834 |
زبان مقاله منتشر شده |
fa |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
1 |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|