|
Avicenna Journal of Dental Research، جلد ۶، شماره ۲، صفحات ۰-۰
|
|
|
عنوان فارسی |
Comparison the Accuracy of the Cone-Beam Computed Tomography With Digital Direct Intraoral Radiography, in Assessment of Periodontal Osseous Lesions |
|
چکیده فارسی مقاله |
Background Radiography is as a part of periodontal examination. Early detection of periodontal disease is important in the prevention of tooth loss and patient’s general health. Objectives The objective of this study was to compare diagnostic accuracy of cone-beam computed tomography (CBCT) with digital direct intraoral radiography, in assessment of periodontal osseous lesions. Materials and Methods Fifty interproximal bone losses were evaluated in this study. First, direct digital intraoral radiography (Sopro-La Ciotat-France) was taken, and then CBCT (Newtom 3G, Verona. Italy) was carried out. Periodontal flap surgery was done to achieve the gold standard. The distance between cementoenamel junction (CEJ) and the bottom of the vertical pattern of bone loss or the most coronal level of bone in horizontal pattern was measured. These measurements were analyzed by paired t test. The intraclass correlation coefficient (ICC) was used to evaluate the degree of agreement between observers. Results Accuracy is higher with CBCT in evaluating vertical dimension of periodontal bony defects (0.53 ± 0.59 to 0.56 ± 0.45) (P < 0.001). ICC shows high level of agreement between observers in two image modality. Conclusions We conclude that CBCT and digital images can be used in periodontal bone assessments; each modality should be chosen based on defect type and patient’s specific characteristics. |
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
Comparison the Accuracy of the Cone-Beam Computed Tomography With Digital Direct Intraoral Radiography, in Assessment of Periodontal Osseous Lesions |
|
چکیده انگلیسی مقاله |
Background Radiography is as a part of periodontal examination. Early detection of periodontal disease is important in the prevention of tooth loss and patient’s general health. Objectives The objective of this study was to compare diagnostic accuracy of cone-beam computed tomography (CBCT) with digital direct intraoral radiography, in assessment of periodontal osseous lesions. Materials and Methods Fifty interproximal bone losses were evaluated in this study. First, direct digital intraoral radiography (Sopro-La Ciotat-France) was taken, and then CBCT (Newtom 3G, Verona. Italy) was carried out. Periodontal flap surgery was done to achieve the gold standard. The distance between cementoenamel junction (CEJ) and the bottom of the vertical pattern of bone loss or the most coronal level of bone in horizontal pattern was measured. These measurements were analyzed by paired t test. The intraclass correlation coefficient (ICC) was used to evaluate the degree of agreement between observers. Results Accuracy is higher with CBCT in evaluating vertical dimension of periodontal bony defects (0.53 ± 0.59 to 0.56 ± 0.45) (P < 0.001). ICC shows high level of agreement between observers in two image modality. Conclusions We conclude that CBCT and digital images can be used in periodontal bone assessments; each modality should be chosen based on defect type and patient’s specific characteristics. |
|
کلیدواژههای انگلیسی مقاله |
|
|
نویسندگان مقاله |
ژانت مرادی حقگو | janet moradi haghgoo department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
عباس شکری | abbas shokri department of radiology, school of dentistry, hamadan university of medical sciences, hamadan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
امین خدادوستان | amin khodadoustan department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
معصومه خوشحال | masoumeh khoshhal department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
نازلی ربیع نژاد | nazli rabienejad department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran; department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran. tel 98-8138381085, fax 98-8138381085
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
مریم فرهادیان | maryam farhadian department of epidemiology and biostatistics, school of public health, hamadan university of medical sciences, hamadan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)
|
|
نشانی اینترنتی |
http://www.avicennajdr.com/index.php?page=article&article_id=21952 |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
10.17795/ajdr-21952 |
زبان مقاله منتشر شده |
fa |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
research-article |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|