|
Avicenna Journal of Dental Research، جلد ۸، شماره ۲، صفحات ۰-۰
|
|
|
عنوان فارسی |
Accuracy of Working Length Determination in Root Canal Treatment Using Different Algorithms |
|
چکیده فارسی مقاله |
Conclusions According to the results of this study, the accuracy of the file length in improved digital images showed no significant difference in comparison with the actual file length. Materials and Methods Using an analytical-diagnostic method, an access cavity was prepared in 36 mandibular and maxillary premolar teeth. A file # 15 was inserted into the canal of each tooth until the tip of the file was observed, then the files were retracted 0.5 mm. The teeth were then placed in an acrylic block, and finally, a radiograph was taken of the blocks. Thereafter, the file in each canal was taken out and measured using a digital caliper. The obtained measurement was the real length of the file. The saved images underwent modifications using different algorithms of image processing. The working length was observed on a monitor under standard conditions. Data were analyzed by t- test using SPSS (ver. 17). Background Determination of working length has great significance in root canal treatments. For this purpose, analog radiography has been replaced by digital radiography. Despite numerous studies, there is still no accurate information about the resolution of these images. Results Based on the findings of this study, no significant difference was observed between the main image, the images processed with the emboss, enhancement, sharpen, and negative algorithms, and the actual file size regarding the means of error. None of the indices had a statistically significant difference with the actual file length (P > 0.05). Objectives The aim of this study was to assess the accuracy of working length determination in root canal treatment using different algorithms in digital radiography. |
|
کلیدواژههای فارسی مقاله |
Radiography،Dental،Digital،Root Canal Therapy |
|
عنوان انگلیسی |
Accuracy of Working Length Determination in Root Canal Treatment Using Different Algorithms |
|
چکیده انگلیسی مقاله |
Conclusions According to the results of this study, the accuracy of the file length in improved digital images showed no significant difference in comparison with the actual file length. Materials and Methods Using an analytical-diagnostic method, an access cavity was prepared in 36 mandibular and maxillary premolar teeth. A file # 15 was inserted into the canal of each tooth until the tip of the file was observed, then the files were retracted 0.5 mm. The teeth were then placed in an acrylic block, and finally, a radiograph was taken of the blocks. Thereafter, the file in each canal was taken out and measured using a digital caliper. The obtained measurement was the real length of the file. The saved images underwent modifications using different algorithms of image processing. The working length was observed on a monitor under standard conditions. Data were analyzed by t- test using SPSS (ver. 17). Background Determination of working length has great significance in root canal treatments. For this purpose, analog radiography has been replaced by digital radiography. Despite numerous studies, there is still no accurate information about the resolution of these images. Results Based on the findings of this study, no significant difference was observed between the main image, the images processed with the emboss, enhancement, sharpen, and negative algorithms, and the actual file size regarding the means of error. None of the indices had a statistically significant difference with the actual file length (P > 0.05). Objectives The aim of this study was to assess the accuracy of working length determination in root canal treatment using different algorithms in digital radiography. |
|
کلیدواژههای انگلیسی مقاله |
Radiography,Dental,Digital,Root Canal Therapy |
|
نویسندگان مقاله |
صنم میربیگی | sanam mirbeygi department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iran
مریم کاظمی پور | maryam kazemipoor department of endodontics, shahid sadoughi university of medical sciences, yazd, ir iran
سحر قانع | sahar ghane department of oral and maxillofacial rafiology, rafsanjan university of medical science, rafsanjan, ir iran
سیمین شفیعی | simin shafiei department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iran; department of oral and maxilofacial radiology, school of dentistry, shahid sadoughi university of medical sciences, emam st. dahe fajr blv., yazd, ir iran. tel 98-3536255881-4; 98-9126887642, fax 98-3536250344
|
|
نشانی اینترنتی |
http://www.avicennajdr.com/index.php?page=article&article_id=27246 |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
10.17795/ajdr-27246 |
زبان مقاله منتشر شده |
fa |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
1 |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|