Avicenna Journal of Dental Research، جلد ۸، شماره ۲، صفحات ۰-۰

عنوان فارسی Accuracy of Working Length Determination in Root Canal Treatment Using Different Algorithms
چکیده فارسی مقاله Conclusions According to the results of this study, the accuracy of the file length in improved digital images showed no significant difference in comparison with the actual file length. Materials and Methods Using an analytical-diagnostic method, an access cavity was prepared in 36 mandibular and maxillary premolar teeth. A file # 15 was inserted into the canal of each tooth until the tip of the file was observed, then the files were retracted 0.5 mm. The teeth were then placed in an acrylic block, and finally, a radiograph was taken of the blocks. Thereafter, the file in each canal was taken out and measured using a digital caliper. The obtained measurement was the real length of the file. The saved images underwent modifications using different algorithms of image processing. The working length was observed on a monitor under standard conditions. Data were analyzed by t- test using SPSS (ver. 17). Background Determination of working length has great significance in root canal treatments. For this purpose, analog radiography has been replaced by digital radiography. Despite numerous studies, there is still no accurate information about the resolution of these images. Results Based on the findings of this study, no significant difference was observed between the main image, the images processed with the emboss, enhancement, sharpen, and negative algorithms, and the actual file size regarding the means of error. None of the indices had a statistically significant difference with the actual file length (P > 0.05). Objectives The aim of this study was to assess the accuracy of working length determination in root canal treatment using different algorithms in digital radiography.
کلیدواژه‌های فارسی مقاله Radiography،Dental،Digital،Root Canal Therapy

عنوان انگلیسی Accuracy of Working Length Determination in Root Canal Treatment Using Different Algorithms
چکیده انگلیسی مقاله Conclusions According to the results of this study, the accuracy of the file length in improved digital images showed no significant difference in comparison with the actual file length. Materials and Methods Using an analytical-diagnostic method, an access cavity was prepared in 36 mandibular and maxillary premolar teeth. A file # 15 was inserted into the canal of each tooth until the tip of the file was observed, then the files were retracted 0.5 mm. The teeth were then placed in an acrylic block, and finally, a radiograph was taken of the blocks. Thereafter, the file in each canal was taken out and measured using a digital caliper. The obtained measurement was the real length of the file. The saved images underwent modifications using different algorithms of image processing. The working length was observed on a monitor under standard conditions. Data were analyzed by t- test using SPSS (ver. 17). Background Determination of working length has great significance in root canal treatments. For this purpose, analog radiography has been replaced by digital radiography. Despite numerous studies, there is still no accurate information about the resolution of these images. Results Based on the findings of this study, no significant difference was observed between the main image, the images processed with the emboss, enhancement, sharpen, and negative algorithms, and the actual file size regarding the means of error. None of the indices had a statistically significant difference with the actual file length (P > 0.05). Objectives The aim of this study was to assess the accuracy of working length determination in root canal treatment using different algorithms in digital radiography.
کلیدواژه‌های انگلیسی مقاله Radiography,Dental,Digital,Root Canal Therapy

نویسندگان مقاله صنم میربیگی | sanam mirbeygi
department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iran


مریم کاظمی پور | maryam kazemipoor
department of endodontics, shahid sadoughi university of medical sciences, yazd, ir iran


سحر قانع | sahar ghane
department of oral and maxillofacial rafiology, rafsanjan university of medical science, rafsanjan, ir iran


سیمین شفیعی | simin shafiei
department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iran; department of oral and maxilofacial radiology, school of dentistry, shahid sadoughi university of medical sciences, emam st. dahe fajr blv., yazd, ir iran. tel 98-3536255881-4; 98-9126887642, fax 98-3536250344



نشانی اینترنتی http://www.avicennajdr.com/index.php?page=article&article_id=27246
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi) 10.17795/ajdr-27246
زبان مقاله منتشر شده fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات