|
Avicenna Journal of Dental Research، جلد ۸، شماره ۴، صفحات ۰-۰
|
|
|
عنوان فارسی |
Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic |
|
چکیده فارسی مقاله |
Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18). The overall results of this study were similar to other studies. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side). Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. |
|
کلیدواژههای فارسی مقاله |
Dosimetry،Panoramic Radiography،Spiral Tomography |
|
عنوان انگلیسی |
Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic |
|
چکیده انگلیسی مقاله |
Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18). The overall results of this study were similar to other studies. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side). Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. |
|
کلیدواژههای انگلیسی مقاله |
Dosimetry,Panoramic Radiography,Spiral Tomography |
|
نویسندگان مقاله |
احسان حکمتیان | ehsan hekmatian assistant professor, torabinejad dental research center, department of oral and maxillofacial radiology, school of dentistry, isfahan university of medical sciences, isfahan, ir iran
سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)
روشنک غفاری | roshanak ghaffari assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university khorasgan branch, isfahan, ir iran
سازمان اصلی تایید شده: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
محمد طغیانی | mohammad toghyani dentist, ir iran
میترا کرباسی خیر | mitra karbasi kheir assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university isfahan khorasgan branch , isfahan, ir iran; assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university isfahan khorasgan branch , isfahan, ir iran. tel 98-9134088924
سازمان اصلی تایید شده: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
|
|
نشانی اینترنتی |
http://www.avicennajdr.com/index.php?page=article&article_id=24431 |
فایل مقاله |
اشکال در دسترسی به فایل - ./files/site1/rds_journals/335/article-335-315704.pdf |
کد مقاله (doi) |
10.17795/ajdr-24431 |
زبان مقاله منتشر شده |
fa |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
1 |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|